Li Liang, Jing Liu, Jamie Buryanek and Songlin Zhang
Background: CT-guided core biopsy and fine needle aspiration have been used for diagnosis of peripheral lung lesions, and both methods have advantages and disadvantages. In our institution, CT-guided core needle biopsy with onsite cytology adequacy evaluation of touch preparations is the standard method for evaluation of peripheral lung lesions.
Methods: The study was approved by Institutional Review Board. We retrospectively reviewed the cytology reports of all lung core needle biopsies during 2009-2012. The clinical information was collected from chart review.
Results: There were total 215 cases during the study period. The average lesion size (in 190 available cases) was 3.46 cm. The average passes were 3.3/lesion. The final diagnoses included 132 malignancies, 70 benign and 13 atypical. Twenty-four cases had follow-up resections. There were two false negative diagnoses due to sample errors and there was no false positive case with a positive predictive value of 100%. The final adequate rate was 99.5% (214/215), and only one case was unsatisfactory. In the 204 patients with available information of post-procedure chest X-ray, 140 (68.6%) had no pneumothorax, and 64 (31.4%) had pneumothorax including 48 mild (23.5%), 3 moderate (1.5%), 2 severe (1%), 3 tension pneumothorax (1.5%), and 8 with chest tubes placed during procedure (3.9%).
Conclusions: Our study showed that CT-guided core biopsy with onsite cytology evaluation has high adequate and low atypical rates. Lung core biopsy can provide more accurate tumor classification and specific diagnoses for non-neoplastic lesions. Adequate tissue is often available for molecular study. The complication rate of pneumothorax in core needle biopsy is compatible to that of fine needle aspiration.
Share this article
Journal of Cytology & Histology received 2476 citations as per Google Scholar report