Saulo de Tarso Zacarias Machado*,Aline Rodrigues Rezende,Solange Gennari,Carlos Adam Conte-Junior,Marion Costa,C�sar Lázaro de la Torre,Evelise Oliveira Telles
Objective: A study aimed at the validation of a high performance liquid chromatography (HPLC) method for detection and quantification of ivermectin (IVM) in commercial milk. Method: After a liquid-liquid extraction with acetonitrile and hexane, a derivatization with a mixture of trifluoroacetic acid and trifluoroacetic anhydride was performed. Chromatography conditions were a C8 column, a fluorescent detector (Ex. 360; Em. 470 nm), a run time of 25 minutes and an isocratic elution at 30°C. The methodology was validated in terms of selectivity, linearity, precision, recovery, limit of quantification (LoQ), limit of detection (LoD), and robustness. Results: The method showed an adequate linearity and selectivity (r2=0.999) with an elution time of 13.909 minutes. However, the repeatability and intermediate precision showed RSD values above of 20% and recovery between 37 to 79%. The calculated LoD and LoQ were 2.50 and 5.00 ng/ml respectively. Robustness showed a significant variation on the analytical method with small changes in heating time during the derivatization and flow rate of chromatography system. Conclusion: The HPLC-fluorescence method showed results partially satisfactory and could be the used for IVM detection in commercial milk samples.
PDFShare this article
Journal of Experimental Food Chemistry received 389 citations as per Google Scholar report