GET THE APP

..

Biosensors & Bioelectronics

ISSN: 2155-6210

Open Access

Organic Sensor for the Detection of Ammonium

Abstract

Laghlimi C, Smaini MA, Maallah R, Touzara S, El Qouatli S and Chtaini A*

The electrochemical behavior of ammonium was investigated at Ethylene Diamine Tetra-Acetic -modified carbon paste electrode (EDTA-CPE) in NaCl solution. A method was developed for the detection of the trace of this product, based on their redox reaction. The redox peaks of ammonium were observed around -0.50 V and 0.50 V (vs. SCE) in cyclic voltammetry. Experimental conditions were optimized by varying the accumulation time, EDTA loading and measuring solution pH. Calibration plots were linear under the optimized parameters over the herbicides concentration range 0.8 and 16 mmol L-1, with a detection and quantification limits about 9.38.10-7 mol L-1 and 3.21.10-6 mol L-1, respectively.

PDF

Share this article

Google Scholar citation report
Citations: 1751

Biosensors & Bioelectronics received 1751 citations as per Google Scholar report

Biosensors & Bioelectronics peer review process verified at publons

Indexed In

 
arrow_upward arrow_upward