Medanta, The Medicity, Gurgaon 122001
India
Research Article
Comparison of Geometrical Uncertainties in Breast Radiation Therapy with Different Immobilization Methods
Author(s): Kanan Jassal, Bisht S, Kataria T, Sachdev K, Choughle A and Supe SKanan Jassal, Bisht S, Kataria T, Sachdev K, Choughle A and Supe S
To compare the set-up uncertainties in breast radiation therapy using two different immobilization methods: vacuum cushion (VC) and standard breast board (BB). The data set comprises of 26 breast cases were divided into two groups based on the type of immobilization used for their radiotherapy treatment, either intensity-modulated radiotherapy (IMRT) or volumetric arc modulated radiotherapy (VMAT). The vacuum cushion group consisted of 14 patients with 143 exposures and the breast board group consisted of 12 patients with 120 exposures. Set-up errors in mediolateral (ML), craniocaudal (CC) and anterioposterior (AP) directions were determined using grey scale matching between the baseline reference and online acquired images by cone beam computed tomography (CBCT) scan. Systematic error (Σ), random error (σ) and mean displacement vector (M) were calculated for both the grou.. Read More»
DOI:
10.4172/2155-9619.1000140
Nuclear Medicine & Radiation Therapy received 706 citations as per Google Scholar report