Department of Chemical Science, Acharya Nagarjuna University, Guntur, India
Commentary
Analytical Method for Determination of Amphotericin
Author(s): S Lakshmi Swamy*
By utilising RP-HPLC with UV detection, a straightforward, sensitive, and precise analytical has been established to estimate amphotericin
in pharmaceutical effluents that the pharmaceutical industry are discharging into aquatic environments. The devised approach is extremely
accurate and sensitive to detect amphotericin at concentrations of less than 0.1ppm-5ppm. For the measurement of Amphotericin in effluents or
pharmaceutical industry washouts, a reversed-phase high performance liquid chromatography (RP-HPLC) method was created and validated.
On a Symmetry C-18 column (250mm 4.6mm i.d., 5.0m), the separation was accomplished using a citrate buffer with a pH of 4.5 as the buffer,
and a combination of 400mL buffer and 600mL acetonitrile in isocratic mode as the mobile phase, all at a flow rate of 1.2 mL/min. A UV detector
operating at 383 nm was used for dete.. Read More»
DOI:
10.37421/2150-3494.2022.13.307
Chemical Sciences Journal received 912 citations as per Google Scholar report