GET THE APP

Time-dependent Deformation Reduction in Gold Orthotic Screws
..

Oral Health Case Reports

ISSN: 2471-8726

Open Access

Editorial - (2022) Volume 8, Issue 3

Time-dependent Deformation Reduction in Gold Orthotic Screws

Francois Japhet*
*Correspondence: Francois Japhet, Department of Medical and Digital Engineering, Hanyang University, Seoul, Korea, Email:
Department of Medical and Digital Engineering, Hanyang University, Seoul, Korea

Received: 17-Apr-2022, Manuscript No. OHCR-22-73211; Editor assigned: 20-Apr-2022, Pre QC No. P-73211; Reviewed: 25-Apr-2022, QC No. Q-73211; Revised: 04-May-2022, Manuscript No. R-73211; Published: 08-May-2022 , DOI: 10.37421/2471-8726.2022.8.55
Citation: Japhet, Francois. “Time-dependent Deformation Reduction in Gold Orthotic Screws.” Oral Heath Case Rep 8 (2022): 55.
Copyright: © 2022 Japhet F. This is an open-access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.

Editorial

The majority of implant systems now on the market use screws of one kind or another to unite vertically stacked parts so that prosthesis can be attached to the top of the implant body directly or indirectly. Preload is the compressive force produced when a threaded fastener is tightened. Such a system's mechanics are extremely complicated, and nothing is understood about the precise makeup of the interface or the interactions that take place before, during, and after the tightening process [1]. Engineering professionals understand that preload loss is normal once a joint is tightened due to the contacting surfaces of contacting surfaces by frequent plastic deformation.

Although loosening of individual prosthetic components with respect to one another and the implant body is one of the most frequently reported prosthetic complications in the dental implant literature to date, particularly in single-tooth restorations, little fundamental research on the issue has been published. Multiple factors influence the amount of compression or preload that a particular system generates [2]. These factors include the screw joint's and the material being clamped's elastic moduli, the coefficient of friction between the surfaces with sliding contacts, component fit, lubrication, the applied torque and its velocity, and the system's temperature.

The screw head design to this list and showed that flathead gold screws offered the best values for a given torque. Preload is dispersed to some extent even without applying strain to a bolted joint, as seen by monitoring its performance over time. Localized plastic deformation and burnishing of surface flaws happen when the threads of a fastener meet under compression in both the dynamic and static phases. As a result, the system's surface friction is reduced, and preload gradually decreases over time. This may help to partially explain the joints alleged "settling." The embedment relaxation of the contacting surfaces may cause up to 10% of the initial preload produced by the single application of a torquing moment in a threaded fastener system to be lost. This might decrease by anywhere between 5% and 40% as a result of embedding relaxation. This value is significantly influenced by how frequently a joint has been tightened and released.

The potential for preload variations in a system of threaded fasteners that is standardised. Preload for a given applied torque changes as a result of repeated tightening and releasing processes because system friction decreases with each cycle. With each cycle, it can be observed that the screw's applied rotation arc grows. Because of the friction between the mating parts, there will be some residual strain in the screw shaft after it has been tightened to provide a clamping force. When the frictional resistance caused by the preload beneath the screw head is overcome by eccentric loading, the screw will then tend to unwind to a passive state [3].

After the torque-generating component is taken out of the steel fastener, up to 50% of the reactive torsion dissipates. The preload in the system may actually rise if the frictional resistance at the clamping surfaces is larger than that at the contacting threaded surfaces. Embedding relaxation's effects most likely hide this [4]. Two stages of the loosening process. The first situation includes the slipping of the joint surfaces and is caused by the application of transverse and axial forces that are strong enough to overcome the frictional and compressive forces that hold the contacting surfaces in place. The second phase starts when the preload is so low that external pressures and vibrations start to "back off" the mating threads. When this point is reached, the clamped surfaces separate and the screw joint stops working. In this situation, the screw runs the risk of being loaded in flexion and breaking. This has effects on scenarios involving cantilevered prosthetics [5].

Conflict of Interest

None.

References

  1. Kaufman, Eliaz, and Ira B. Lamster. "The diagnostic applications of saliva—a review." Crit rev oral boil med 13(2002): 197-212.
  2. Google Scholar, Crossref, Indexed at

  3. Mandel, I. D. “The functions of saliva." J dent res 66(1987): 623-627.
  4. Google Scholar, Crossref, Indexed at

  5. Aps, Johan KM, and Luc C. Martens. "The physiology of saliva and transfer of drugs into saliva." Forensic sci int150(2005): 119-131.
  6. Google Scholar, Crossref, Indexed at

  7. Mandel, Irwin D. "The diagnostic uses of saliva." J Oral Pathol  Med 19(1990): 119-125.
  8. Google Scholar, Crossref, Indexed at

  9. Dodds, Michael WJ, Dorthea A. Johnson, and Chih-Ko Yeh. "Health benefits of saliva: a review." Journal of dent 33(2005): 223-233.
  10. Google Scholar, Crossref, Indexed at

arrow_upward arrow_upward