GET THE APP

Dual pH-sensitive fluorophore ratiometric nanosensor with an extended dynamic range and tuneable pKa
..

Biosensors & Bioelectronics

ISSN: 2155-6210

Open Access

Dual pH-sensitive fluorophore ratiometric nanosensor with an extended dynamic range and tuneable pKa


International Conference and Exhibition on Biosensors & Bioelectronics

May 14-16, 2012 Embassy Suites Las Vegas, USA

Kirti Rani

Posters: J Biosens Bioelectron

Abstract :

Previously reported pH-sensitive nanosensors, consisting of commercially available fluorophores, are restricted to a defined pKa and a limited pH range of measurement. By immobilising two pH-sensitive fluorophores and a reference fluorophore in a biocompatible matrix, we have produced a pH-sensitive nanoparticle with an extended measurement range and tuneable pKa. Dual pH-sensitive fluorophore ratiometric nanosensors, with a diameter of approximately 40 nm, were prepared by entrapping combinations pH-sensitive fluorophores fluorescein isothiocyanate dextran (FITC-D) and Oregon Green® dextran (OG-D) and a reference fluorophore 5-(and-6)-carboxytetramethylrhodamine dextran (TAMRA-D) in an acrylamide matrix. Typically, pHsensitive nanosensors containing a single pH-sensitive fluorophore have an effective dynamic range, of approximately 1.15 pH units. Whereas for nanosensors containing both FITC-D and OG-D, combined in a 1:1 ratio, the effective dynamic range is maximised, to 2.01 pH units. The pKa of pH sensitive nanosensors can be tuned by varying the initial concentration of OG-D and FITC-D, during nanoparticle preparation. Through increases in the ratio of FITC-D to OG-D the pKa of the nanosensor can be tuned, from 4.8 to 6.4. Extended dynamic range nanosensors will be able to make ratiometric measurements over the full physiological pH range, from pH 4.0 to 7.5, eliminating the need to perform multiple experiments with more than one type of pH-sensitive nanosensor. In addition, tuneable nanosensors can be engineered to specific pKa so that sensitivity in a narrow pH range can be maximised.

Biography :

Veeren Chauhan completed his master?s degree from the University of Manchester and is currently studying towards a PhD, in biosensing with nanosensors, at the University Of Nottingham School of Pharmacy. He is a practicing community pharmacist, having had roles previously in industry and hospital settings.

Google Scholar citation report
Citations: 6207

Biosensors & Bioelectronics received 6207 citations as per Google Scholar report

Biosensors & Bioelectronics peer review process verified at publons

Indexed In

 
arrow_upward arrow_upward