Buta Singh Sidhu, Gurpreet Singh2 and Hazoor Singh
MRS Punjab Technical University, India
Punjabi University, India
Posters & Accepted Abstracts: J Material Sci Eng
The main aim of this study is to investigate the corrosion behavior of plasma sprayed hydroxyapatite (HA) and hydroxyapatite� Calcium Phosphate (CaP) coatings on AISI 304 specimen in simulated body fluid (SBF) for biomedical applications. In HA�CaP coating 10 wt% CaP was mixed with HA. The coatings was characterized by x-ray diffraction (XRD), scanning electron microscopy (SEM) and energy dispersive X-ray spectroscopy (EDS) to investigate the crystallinity, microstructure and morphology. Electrochemical potentiodynamic tests were performed to determine the corrosion resistance of uncoated and coated substrates. After the electrochemical corrosion testing the exposed samples were examined by XRD, SEM and EDS. The result of electrochemical study reveals improvement in corrosion resistance of AISI 304 after HA coating.
Journal of Material Sciences & Engineering received 3677 citations as per Google Scholar report