GET THE APP

Optical coherence characteristics of suspected hypersensitivity reaction following ultimaster drugeluting stent implantation
..

Cardiovascular Diseases & Diagnosis

ISSN: 2329-9517

Open Access

Optical coherence characteristics of suspected hypersensitivity reaction following ultimaster drugeluting stent implantation


28th International Conference on Cardiology and Healthcare

August 09-11, 2018 Abu Dhabi, UAE

Warkaa Alshamkhani

Sandwell and West Birmingham Trust, UK

Scientific Tracks Abstracts: J Cardiovasc Dis Diagn

Abstract :

The number of bioresorbable polymer coating stents that are commercially available is increasing. They present some potential benefits by eliminating the need for long-term polymer exposure as well as other appealing characteristics that facilitate and enhance endothelial coverage. Since its launch, several trails investigated the safety and efficacy of the bioresorbable stents. In 2014, the Century II trial compared the Ultimaster with Xience Everolimus-eluting stent with the circumferentially-coated durable polymer (Abbot Vascular). This trial concluded that the ultimaster is non-inferior to Xience Everolimus DES in its primary endpoint which was target vessel failure TVF. In another word, it showed excellent performance at a low rate of risk events. However, less is known regarding the effect of these new devices. The type of ISR and how itâ??s different regarding time course, morphology and more importantly in the clinical events. A 59-year-old female presented to the cardiology clinic with a history of recent angina. Her risk factors included dyslipidemia, type-II diabetes mellitus and previous PCI to both the Right Coronary Artery (RCA) with Terumo Ultimaster 2.5Ã?38 mm Stent and the Circumflex artery (CX) using Abbot Xience Pro 2.25Ã?23 m for non-ST elevation myocardial infarction in 2017. Stress echocardiogram proved reversible ischaemia in LAD and RCA regions and repeat catheterisation revealed an image angiographically compatible with significant In-Stent Restenosis (ISR) at mid-RCA stent; the CX showed moderate lesion just proximal to the previous stent which was widely patent and a severe proximal LAD disease. Surgical MDT was in favour of PCI as RCA anatomy distal to the stent is not graftable. For the RCA ISR treatment, we opted to perform Optical Coherence Tomography (OCT) for better characterisation of the lesion; this showed appropriate deployment of the stent, some areas with micro vessels and per-strut lowintensity signals suggestive of endothelial dysfunction, intimal hyperplasia with interestingly focal areas of inflammation suggestive of polymer hypersensitivity. The ISR was treated with DES pre-dilated for optimisation. The global literature and data on Ultimaster ISR and management (a paclitaxel-coated balloon or a drug-eluting stent) are scarce and to the very best of our knowledge, this case is one of the first descriptions of Ultimaster in-stent restenosis (or failure) secondary to possibly polymer allergic reaction. The use of intracoronary OCT imaging as an advanced imaging tool provided us with a unique opportunity to understand and manage complex and infrequent conditions like this one.

Biography :

E-mail: warkaa_saeed@yahoo.com

 

Google Scholar citation report
Citations: 427

Cardiovascular Diseases & Diagnosis received 427 citations as per Google Scholar report

Cardiovascular Diseases & Diagnosis peer review process verified at publons

Indexed In

 
arrow_upward arrow_upward