GET THE APP

Radiological protection for newly built experimental setup with low energy X-ray beams
..

Astrophysics & Aerospace Technology

ISSN: 2329-6542

Open Access

Radiological protection for newly built experimental setup with low energy X-ray beams


International Conference on Astronomy, Astrophysics and Astrobiology

May 30-31, 2018 Osaka, Japan

Joanna Czub, Janusz Braziewicz, Adam Wasilewski, Anna Wysocka-Rabin and Andrzej Wojcik

Jan Kochanowski University, Poland
National Centre for Nuclear Research, Poland
Stockholm University, Sweden

Posters & Accepted Abstracts: J Astrophys Aerospace Technol

Abstract :

The new experimental setup for radiobiological studies using low energy X-ray beams emitted by diffraction X-ray tube (C-tech tube, no. 9430 922 00291, PANalytical, Holland) created at Jan Kochanowski University, Institute of Physics, Kielce, Poland. Radiological protection for this system was determined, thanks to simulation and measurements. MonteCarlo (MC) calculation was performed using Fluka 2011 version 2c.4 code. Measurements were done using data registered by semiconductor microspectrometer SPEC500 (Ritec Ltd., Latvia). MC calculation and measurements, showed effective dose values around experimental setup. The registered total effective dose was equal to 3.4 mSv per year. This value is lower than 6 mSv per year which means that new experimental system fulfills expectations for radiological devices in Poland.

Biography :

Joanna Czub works as a Physicist at Jan Kochanowski University in Kielce, Poland. She has experience in interdisciplinary research on the borderline of physics and biology, particularly in radiobiology.