GET THE APP

Real-time sensing of microbial contaminants in potable water
..

Biosensors & Bioelectronics

ISSN: 2155-6210

Open Access

Real-time sensing of microbial contaminants in potable water


2nd International Conference and Exhibition on Biosensors & Bioelectronics

June 17-19, 2013 Hilton Chicago/Northbrook, USA

Ian Pepper, Samendra Sherchan and Shane Snyder

Scientific Tracks Abstracts: J Biosens Bioelectron

Abstract :

Potable waters in distribution systems are vulnerable to contamination from accidental or deliberate intrusion events. Contaminants can be chemical and/or microbial, and result in adverse health effects. Therefore the time required for the detection of the contaminant determines the magnitude of the adverse public health effect. We utilized real-time sensors to detect both Escherichia coli (E. coli) and Bacillus spores in a potable water distribution system. The study was conducted at the University of Arizona Real-Time Sensor Lab within the UA Water Village. Two different sensors were utilized. One sensor utilized multiangle laser light scattering (MALS) to detect particulates. The other sensor used light scattering plus fluorescence emission from nicotinamide adenine dinucleotide phosphate (NADP) and riboflavin. The bacterium E. coli could be detected in distilled water or tap water in real-time over a concentration range of 106 CFU per ml -103 CFU per ml. In contrast, Bacillus thuringiensis, a surrogate for Bacillus anthracis was used as a source of bacterial spores, which would be detected in real time over a concentration range of 105 per ml - 102 per ml. The sensors were also utilized to document the absence of viable E. coli cells following advanced oxidation treatment of the water via ultraviolet light and hydrogen peroxide. Thus, these sensors could be utilized in real-time to either detect microbial contaminants, or document the destruction of microbial contaminants. In either case, such sensors could verify the safety of potable water, with respect to potential microbial contaminants

Biography :

Ian Pepper obtained his Ph.D. at the Ohio State University. He is currently a professor of environmental microbiology at the University of Arizona where he also serves as co-director of the UA Water and Energy Sustainable Technology (WEST) Center. He has published over 170 peer review publications and 8 textbooks. Dr. Pepper is a Fellow of the American Association for the Advancement of Science (AAAS); the American Society for Microbiology; the Soil Science Society of America; and the American Society of Agronomy.

Google Scholar citation report
Citations: 1751

Biosensors & Bioelectronics received 1751 citations as per Google Scholar report

Biosensors & Bioelectronics peer review process verified at publons

Indexed In

 
arrow_upward arrow_upward