GET THE APP

Suitability of electrolyzed oxidizing water for the disinfection of hard surfaces and equipment in radiology
..

Journal of Bioengineering & Biomedical Science

ISSN: 2155-9538

Open Access

Suitability of electrolyzed oxidizing water for the disinfection of hard surfaces and equipment in radiology


International Conference on Significant Advances in Biomedical Engineering

April 27-29, 2015 Philadelphia, USA

Robert Pintaric1, Joze Matela1 and Stefan Pintaric2

Scientific Tracks Abstracts: J Bioengineer & Biomedical

Abstract :

Background: Hospitals face with increasingly resistant strains of micro-organisms. When it comes to disinfection, individual parts of electronic equipment of angiology diagnostics such as patient couches of computer tomography (CT) and magnetic resonance imaging (MRI) scanners prove to be very hard to disinfect. Disinfectants of choice are therefore expected to possess properties such as rapid, residue-free action without any damaging effect on the sensitive electronic equipment. This paper discusses the use of the neutral electrolyzed oxidizing water (EOW) as a biocide for the disinfection of diagnostic rooms and equipment. Methods: The CT and MRI rooms were aerosolized with EOW using aerosolization device. The presence of micro-organisms before and after the aerosolization was recorded with the help of sedimentation and cyclone air sampling. Total body count (TBC) was evaluated in absolute and log values. Results: The number of micro-organisms in hospital rooms was low as expected. Nevertheless, a possible TBC reduction between 78.99?92.50% and 50.50?70.60% in log values was recorded. Conclusions: The research has shown that the use of EOW for the air and hard surface disinfection can considerably reduce the presence of micro-organisms and consequently the possibility of hospital infections. It has also demonstrated that the sedimentation procedure is insufficient for the TBC determination. The use of Biocide aerosolization proved to be efficient and safe in all applied ways. Also, no eventual damage to exposed devices or staff was recorded.

Biography :

Robert Pintaric has completed his studies of radiology in 2000 and then worked in the field of angiography and interventional radiology at the Institute of Radiology, University Medical Centre Ljubljana. Currently working at the Department of Radiology at the University Medical Centre in Maribor from 2007. He is actively involved in the research field of magnetic resonance 3 T and disinfection of diagnostic facilities, equipment, surfaces and air systems with electro-oxidizing water.

Google Scholar citation report
Citations: 307

Journal of Bioengineering & Biomedical Science received 307 citations as per Google Scholar report

Journal of Bioengineering & Biomedical Science peer review process verified at publons

Indexed In

 
arrow_upward arrow_upward